This is a BRAND NEW Sokkia SET 3230RM Auto Pointing Reflectorless Motorized Total Station with RC-PR2 Remote Control System. This system has never been used. It will include a used SDR-33 Data Collector 1MB Expert and has a brand new coiled cable.
All items included in this are the following:
1. SET 3230RM Total Station
2. Battery (BDC45) 2 each
3. Battery Charger (CDC56)
4. AC Cable (EDC34/35)
5. Tubular Compass (CP7)
6. Lens cap
7. Lens hood
8. Plumb bob
9. Tool pouch
10. Screwdriver
11. Lens brush
12. Adjusting pin
13. Cleaning cloth
14. Vinyl cover
15. Operators manual
16. Laser caution sign-board
17. Carrying case (SC193)
18.Carrying strap
19. RC-PR2 Remote Control System 20. Leica GST120-9 Tripod
Telescope
Length: 171 mm
Aperture: 45 mm (EDM: 48mm)
Magnification: 30x
Image: Erect
Resolving power: 2.5"
Field of view: 1 degree 30'
Minimum focus: 1.3 m
Focussing screw: 1 speed
Reticle illumination: 5 brightness levels
Angle measurement
Horizontal and Vertical circles type:
Increment with 0 index (Both circles adopt diametrical detection)
Angle units: Degree/Gon/Mil (selectable)
Minimum display: 1" (0.2mgon/0.005mil)/5" (1mgon/0.02mil)
Accuracy: SET3230RM: 3" (1mgon)
SET4230RM: 5" (1.5mgon)
(ISO 17123-3: 2001)
Measuring time: Less than .5 sec (repeated measurement)
Automatic compensator: ON (V & H/V)/OFF (selectable)
Type: Liquid 2-axis tilt sensor
Minimum display: Agrees with minimum displayed measurement angle
Range of compensation: + or - 3'
Collimation correction: Yes, No (selectable)
Measuring mode:
Horizontal angle: Right/Left (selectable)
Vertical angle: Zenith 0 degree, Vertical 0 degree, Vertical + or - 90 degree (selectable)
Distance measurement
Measuring method: Coaxial phase-contrast measuring system
Signal source: Red laser diode 690nm
Class 3R
(IEC60825-1 Amd. 2: 2001/FDA CDRH 21 CFR Part 1040.10 and 1040.11 (Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.))
Measuring range: (Using Sokkia's reflective prism/reflective sheet target during normal atmospheric conditions *1/*2 is good atmospheric conditions)
Reflective sheet RS90N-K: 1.3 to 500m (1,640ft)
Reflective sheet RS50N-K: 1.3 to 300m (980ft)
Reflective sheet RS10N-K: 1.3 to 100m (320ft)
Compact prism CP01: 1.3 to 800m (2,620ft)
Standard prism AP01AR X 1: 1.3 to 4,000m (13,120ft)
to 5,000m (16,400ft) *2
Standard prism AP01AR X 3: to 5,000m (16,400ft)
to 6,000m (19,680ft)
Mini prism pole OR1PA: 1.3 to 500m (1,640ft)
Reflectorless (White) *3: 0.3 to 350m (1,140ft)
Reflectorless (Gray) *4: 0.3 to 170m (550ft)
Minimum display: Fine measurement, Rapid measurement: 0.001 m
Tracking measurement: 0.01 m
Maximum slope distance: 9999.999 m
Distance unit: meter/feet/inch (selectable)
Accuracy:
(Using prism)
Fine measurement: + or - (2 + 2 ppm X D) mm
Rapid measurement (single): + or - (5 + 2 ppm X D) mm
(Using reflective sheet target)
Fine measurement: + or - (3 + 2 ppm X D) mm
Rapid measurement (single): + or - (6 + 2 ppm X D) mm
(Reflectorless (White))*3
Fine measurement:
+ or - (3 + 2 ppm X D) mm (0.3 to 200m)
+ or - (5 + 10 ppm X D) mm (over 200 to 350m)
Rapid measurement (single):
+ or - (6 + 2 ppm X D) mm (0.3 to 200m)
+ or - (8 + 10 ppm X D) mm (over 200 to 350m)
(Reflectorless (Gray))*4
Fine measurement:
+ or - (3 + 2 ppm X D) mm (0.3 to 100m)
+ or - (5 + 5 ppm X D) mm (over 100 to 170m)
Rapid measurement (single):
+ or - (6 +2 ppm X D) mm (0.3 to 100m)
+ or - (8 + 5 ppm X D) mm (over 100 to 170m)
Measurement mode: Fine measurement (single/repeat/average)/
Rapid measurement (single)/Tracking (selectable)
Measuring time:
Fine measurement: 1.7 sec. + every 0.9 sec.
Rapid measurement (single): 1.4 sec.
Tracking measurement: 1.4 sec. + every 0.3 sec.
Atmospheric correction:
Tempurature input range: - 30 to 60 degree C (in 1 degree C step)
Pressure input range: 500 to 1,400 hPa (in 1hPa step)
375 to 1,050 mmHg (in 1mmHg step)
ppm input range: -499 to 499 ppm (in 1 ppm step)
Prism constant correction: -99 to 99 mm (in 1 mm step)
Earth curvature and refraction correction: No/Yes K=0.142 or Yes K=0.20 (selectable)
*1 Slight haze, visibility about 20 km, sunny periods, weak scintillation.
*2 No haze, visibility about 40 km, overcast, no scintillation.
*3 Figures when using Kodak Gray Card White side (reflection factor 90%) and brightness level is less than 30000 Ix (a little cloudy).
*4 Figures when using Kodak Gray Card Gray side (reflection factor 18%) and brightness level is less than Ix (a little cloudy).
*3,*4 When performing reflectorless measurement, the possible measurement range and precision will change depending on the target reflection factor, weather conditions and location conditions.
Auto Pointing
Sokkia's reflective prism/reflective target (No haze, visbility about 40 km, cloudy periods, no scintillation)
Signal source: Laser diode (785nm)
Class 1
(IEC60825-1 Amd. 2: 2001/FDA CDRH 21 CFR Part 1040.10 and 1040.11 (Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.))
Measuring range: Sight (in field of view)
Distance:
Standard prism AP01 X 1: 2.0 to 800 m/6.5 to 2600ft
Compact prism CP01: 2.0 to 400 m/6.5 to 1300ft
Mini pole prism OR1PA: 2.0 to 300 m/6.5 to 950ft
Sighting accuracy (Standard deviation):
2.5mm (less than 100m)
5" (more than 100m)
Sighting speed: 3 to 6 sec (100m)
Motor
(No vibration and no wind)
Motion range: 360 degree (Vertical and horizontal)
Rotating time: Less than 10 sec. (when rotating 180 degree) (25 degree C)
Guide Light
Slight haze, visibility about 20 km, sunny periods, weak scintillation)
Light source: LED (red 630 nm/green 524 nm)
Class 1
(IEC60825-1 Amd. 2: 2001/FDA CDRH 21 CFR Part 1040.10 and 1040.11 (Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.))
Distance: 1.3 to 150m
Visible range: Right and Left/Upward and Downward: about + or - 4 degree (about 7m/100m)
Resolving power at center area(width): less than about 4' (about 0.12/100m)
Power Supply
Power source: Ni-MH rechargeable battery BDC45
Battery state indicator: 4 levels
Working duration at 25 degree C:
BDC45: about 3.5 hours (Fine single measurement by face 1 and 2, every 30 sec., using auto-pointing function)
BDC7 (optional accessories): about 7 hours
Charging time: BDC45: about 130 minutes (using CDC56)
(BDC45)
Nominal voltage: 10.8V
(CDC56)
Input voltage: 100 to 240 VAC
Frequency: 50/60Hz
Charging tempurature range: 10 to 40 degree C
External power input: 12.0V
General
Display: LCD graphic display, 120 dots X 64 dots 1 LCD graphic display with illuminator
Operation panel (keyboard): 28 keys + 1 key (soft function, operation, power, light) (trigger key)
Auto power-off: On (instrument powers off if not used for 30 min,)/Off (selectable)
Calendar clock: Provided
Internal memory: about 10000 points
Data output: Asynchronous serial, RS232C compatible
Sensitivity of levels: Plate level: 30"/2 mm
Circular level: 10'/2 mm
Optical plummet: Image: Erect
Magnification: 3X
Minimum focus: 0.5 m
Horizontal and vertical motion: changeable speed using jog dial
Operating tempurature: -20 to 50 degree C
Dust and Water resistance: IPX2 (IEC60529: 1989)
Instrument height: 245 mm from tribrach bottom
202 mm from tribrach dish
202 mm (W) X 171 (D) X 380 (H) mm (with handle)